Motor thermal protection work process

Common faults of motor:Room temperature plugging,Low temperature (-30 ℃) plugging,High temperature (+ 85 ℃) plugging,Overload conditions.The thermal protector has a different working method for motor faults.
1, room temperature plugging thermal protection:
A. The motor output shaft is plugged,Apply a low voltage of 13.5V ± 0.2V to the motor,Thermostat for the first time from closed to off time ≧ 2s,The first break to the closing time ≦ 20s.
B. The motor output shaft plugging,The motor high-speed side of the application of 13.5V ± 0.2V voltage 3 hours,Thermostat for the first time from closed to off time ≧ 2s,The first break to the closing time ≦ 20s.
C. The motor output shaft plugging,The motor low-speed side of the application of 16.0V ± 0.2V voltage,The thermostat first from closed to off time ≦ 15s,The first break to the closing time ≦ 45s.
D. The motor output shaft plugging,On the motor high-speed side of the application of 16.0V ± 0.2V voltage,The thermostat first from closed to off time ≦ 15s,The first break to the closing time ≦ 45s.
 
2, low temperature (-30 ℃) plugging thermal protection:
Place the motor in the -30 ° C ambient box for at least 2 hours,Motor output shaft plugging,On the low-speed side of the motor applied 11.0V ± 0.2V voltage 3 hours,Each time the thermostat is closed from the break time </ = 5 minutes,Each time from the break to the closed ≧ 5s.

3, high temperature (+85 ℃) plugging thermal protection:
Place the motor in a + 85 ° C ambient box for at least 2 hours,Motor output shaft plugging,The motor high-speed side of the application of 13.5V ± 0.2V voltage 3 hours,Each time the thermostat is closed from the opening time ≧ 2s,Each time from off to closed ≦ 2min.
 
4, overload conditions Thermal protection:
A. At room temperature,On the motor high-speed side of the application of 13.5V ± 0.2V voltage,And apply a 5N.m moment to the shaft shaft,Thermostat should be no action within 20 minutes.
 
B. At room temperature,Apply a low voltage of 13.5V ± 0.2V to the motor,And apply a 5N.m moment to the shaft shaft,Thermostat 40 minutes should be no action.
No. Temperature         Voltage   Speed    Condition  Off Time    Closed Time
1    room temperature    13.5V    low         plugging    ≧ 2s         ≦ 20s
2    room temperature     13.5V    high       plugging     ≧ 2s         ≦ 20s
3    room temperature     16.0V    low        plugging     ≦ 15s       ≦ 45s
4   room temperature     16.0V    high       plugging     ≦ 15s       ≦ 45s
5          -30 ℃                 11.0V     low        plugging      ≦ 5min     ≧ 5s
6        + 85 ℃                 13.5V     high       plugging      ≧ 2s        ≦ 2min
7    room temperature   13.5V     high        5 N.m ≧ 20min
8    room temperature     13.5V     low          5 N.m ≧ 40min