Sale 1A, 2A,.... 10A, 20 Amp Small Car blade ATO & ATC Fuse type
- PRODUCT DETAIL
Car fuse classification
Blade fuse
Blade fuses can be divided into:
Ultra small blade fuse, small automobile fuse, medium automobile fuse, large automobile fuse.
Rated currents range from 1-40 amps (A) to 30-120 amps (A) and rated voltages are 32 volts (V).
Fork bolt fuse
Fork-type fuses can be divided into: small fork-type fuses, large fork-type fuses.
Rated currents are 30-150 amps (A) to 40-800 amps (A), and rated voltages are 32/125 volts (V).
Automotive glass tube fuses can be divided into: 6.35 × 30mm glass tube fuses, 6.35 × 31.75mm glass tube fuses, and 10 × 38mm glass tube fuses.
Rated currents range from 0.5-20 amps (A) to 10 × 38mm 20-80 amps (A) and rated voltages are 32 volts (V).
Inspection and replacement
During the use of the car, if any electrical equipment does not work, it may be caused by a blown fuse and needs to be replaced in time.
The method is:
1. Turn off the ignition switch and open the fuse box cover.
2. Replace the fuse.
Precautions:
(1) The fuse should be replaced according to the rated current value indicated on the fuse box cover. Do not use a fuse with a higher rated current.
(2) If the new fuse blows again immediately, the circuit system may be faulty and should be repaired as soon as possible.
(3) Without a spare fuse. In an emergency, you can replace the fuse on other equipment that has no impact on driving and safety.
(4) If a fuse with the same current load cannot be found, a lower current rating than the original fuse can be used instead.
Product Details
Intentions to develop, to use technology to benefit society
Functional Characteristics
Approvals (○ Pending ● Approvals )
Blade fuse
Blade fuses can be divided into:
Ultra small blade fuse, small automobile fuse, medium automobile fuse, large automobile fuse.
Rated currents range from 1-40 amps (A) to 30-120 amps (A) and rated voltages are 32 volts (V).
Fork bolt fuse
Fork-type fuses can be divided into: small fork-type fuses, large fork-type fuses.
Rated currents are 30-150 amps (A) to 40-800 amps (A), and rated voltages are 32/125 volts (V).
Automotive glass tube fuses can be divided into: 6.35 × 30mm glass tube fuses, 6.35 × 31.75mm glass tube fuses, and 10 × 38mm glass tube fuses.
Rated currents range from 0.5-20 amps (A) to 10 × 38mm 20-80 amps (A) and rated voltages are 32 volts (V).
Inspection and replacement
During the use of the car, if any electrical equipment does not work, it may be caused by a blown fuse and needs to be replaced in time.
The method is:
1. Turn off the ignition switch and open the fuse box cover.
2. Replace the fuse.
Precautions:
(1) The fuse should be replaced according to the rated current value indicated on the fuse box cover. Do not use a fuse with a higher rated current.
(2) If the new fuse blows again immediately, the circuit system may be faulty and should be repaired as soon as possible.
(3) Without a spare fuse. In an emergency, you can replace the fuse on other equipment that has no impact on driving and safety.
(4) If a fuse with the same current load cannot be found, a lower current rating than the original fuse can be used instead.
Product Details
Intentions to develop, to use technology to benefit society
Breaking Capacity 分 | Material | Operating Temperature | Soldering conditions |
50 amperes at 32V DC (250mA-5A) |
Substrate – Ceramic/Glsdd Cover Termination -- Sliver over-plated with nickel and tin Element -- Silver |
-40℃~+125℃ |
Wave solder:260℃,≤5S Hand solder: 360℃,≤1S |
Amper Rating | Testing current | Blow Time | |
Min | Max | ||
250mA~5A | 100% | 4 hour | - |
250mA~5A | 200% | 1 s | 60s |
250mA~5A | 250% | - | 5s |
Approvals (○ Pending ● Approvals )
Current Rating | Voltage Rating | Marking |
Norminal Melting I2T(A2sec) |
Approvals |
UL | ||||
D | 0.0004 | ○ | ||
E | 0.0009 | ○ | ||
F | 0.002 | ○ | ||
G | 0.009 | ○ | ||
H | 0.010 | ○ | ||
J | 0.013 | ○ | ||
K | 0.032 | ○ | ||
N | 0.049 | ○ | ||
O | 0.065 | ○ | ||
P | 0.07 | ○ | ||
R | 0.12 | ○ | ||
S | 0.24 | ○ | ||
T | 0.70 | ○ |